Results 1 to 4 of 4
  1. #1
    Member
    Join Date
    Apr 2006
    Location
    White Oak
    Posts
    118

    Water Pressure on Smartcraft

    I recently installed a Smartcraft Monitor on my 250XS and everything works great, except the water pressure, it's reads 0.0. I have a analog Water psi gauge that shows I have good pressure and I have no alarms, but the SC reads 0.0. What do I need to do to get the smartcraft monitor to display the water pressure? I have have tried switching the Pitot sensor with the water pressure sensor to see if it will read pressure, but reads 0.0 as well. I dont think the pressure sensor is bad, I do not no what else to do...


    Modified by RDM0535 at 7:47 AM 11/21/2010

  2.  
  3. Mercury - 3 Liter Moderator EuropeanAM's Avatar
    Join Date
    Apr 2008
    Location
    Greenville, SC (US)
    Posts
    54,227
    #2

    Re: Water Pressure on Smartcraft (RDM0535)

    Have you disconnected the gray tubing from the Block (water) pressure sensor (on the coil plate) to confirm there actually IS water pressure at this hose????

    If yes- have you confirmed that the water pressure data item is enabled in the System Monitor's setup/calibration?



    Dual Mercury Master Technician- for Mercury Outboards, Racing & Mercruiser Sterndrives in Greenville, SC.
    Still consider myself a "Marine Apprentice" after 38 years (learn something new every day).
    Mercury Parts, Mercury Outboards, Smartcraft & Accessories, Injector Service, TDR Reeds- BBC Sponsor

  4. Member
    Join Date
    Apr 2006
    Location
    White Oak
    Posts
    118
    #3

    Re: Water Pressure on Smartcraft (EuropeanAM)

    Yes, there is pressure at the hose. How do you enable it? It is turned on in the "cal1" mode...

  5. Mercury - 3 Liter Moderator EuropeanAM's Avatar
    Join Date
    Apr 2008
    Location
    Greenville, SC (US)
    Posts
    54,227
    #4

    Re: Water Pressure on Smartcraft (RDM0535)

    <table width="90%" cellspacing=0 cellpadding=0 align=center><tr><td>Quote, originally posted by RDM0535 &raquo;</td></tr><tr><td class="quote">Yes, there is pressure at the hose. How do you enable it? It is turned on in the "cal1" mode...
    </td></tr></table>

    The Value shown should be "on" or "1 (digit ONE)".

    If that is how it is, I would recommend that you have someone VERIFY the water pressure shown in the "Block Pressure" data line (with either the Computer Diagnostic System, or with a DDT). This would help to determine if the problem is in the sensor & ECM, or if the problem is actually in your Smartcraft Instrument.



    Dual Mercury Master Technician- for Mercury Outboards, Racing & Mercruiser Sterndrives in Greenville, SC.
    Still consider myself a "Marine Apprentice" after 38 years (learn something new every day).
    Mercury Parts, Mercury Outboards, Smartcraft & Accessories, Injector Service, TDR Reeds- BBC Sponsor

Similar Threads

  1. "Water Pressure 101"- Poppet Valves and Variables with Water Pressure
    By EuropeanAM in forum Mercury - 3 Liter & 3 Liter High Performance
    Replies: 47
    Last Post: 09-26-2012, 10:32 AM
  2. Replies: 6
    Last Post: 04-02-2012, 04:00 AM
  3. Smartcraft water pressure addition
    By FSHRMN1010 in forum Mercury - 3 Liter & 3 Liter High Performance
    Replies: 4
    Last Post: 12-13-2010, 03:29 PM
  4. Smartcraft water pressure
    By Steve M in forum Mercury - 3 Liter & 3 Liter High Performance
    Replies: 2
    Last Post: 11-05-2010, 09:06 AM
  5. water pressure tube - changed fom analogue to smartcraft
    By wallysone in forum Mercury - 3 Liter & 3 Liter High Performance
    Replies: 4